HUATEC GROUP CORPORATION

HUATEC GROUP CORPORATION Professional Non Destructive Testing Equipment

Manufacturer from China
Verified Supplier
17 Years
Home / Products / X-Ray Flaw Detector /

Excellent anti-jamming performance X Ray Flaw Detectors for thin iron plate , aluminum

Contact Now
HUATEC GROUP CORPORATION
Visit Website
City:beijing
Province/State:beijing
Contact Person:MrJingAn Chen
Contact Now

Excellent anti-jamming performance X Ray Flaw Detectors for thin iron plate , aluminum

Ask Latest Price
Video Channel
Place of Origin :Beijing
Model Number :XXQ-2505
MOQ :1pcs
Packaging Details :Standard export package
Delivery Time :1-4days
Payment Terms :T/T, Paypal, Western Union
Brand Name :HUATEC
Certification :ISO, CE, GOST
Supply Ability :500pcs per month
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Directional radiation portable X-ray flaw detector
(Glass x-ray tube)

XXQ series are suitable for the material directional of thin iron plate, aluminum, rubber and so on, may get very good picture quality and clarity.

Feature:


●Checking the software and hardware itself after start the machine

●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports

●Can adjust exposure parameters with keys ( easy operation.)

●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field

●Can adjust high voltage slowly for protecting X-ray generator

●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.

●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming

●Convenient for repairing and maintenance

●Much more Substance for structure designing, much more convenient for local operation

●Time can be changed for±0.3 according to the power supply net to make the exposure more precise

Specification:

Output voltage

(Kv)

Input

(KW)

Focus spot

(mm)

Beam angle

Max penetration

(mm)

Weight (KG)

Dimensions (mm)

Generator

Controller

Generator

Controller

XXQ-1005

50-100

1.2

0.8X0.8

40°

7

8.5

11

Ф135x555

350x290x160

XXQ-1605

60-160

1.5

0.8X0.8

40°

18

17

11

225x225x600

350x290x160

XXQ-2005

100-200

2.0

1.5X1.5

40°+5°

29

22.5

11

280x280x650

350x290x160

XXQ-2505

150-250

2.5

2.0X2.0

40°+5°

39

33.5

11

320x320x740

350x290x160

XXQ-3005

170-300

3.0

3.5X3.5

40°+5°

50

42

11

335x335x835

350x290x160

XXQ-3205

180-320

3.2

4.0X4.0

40°+5°

55

42

11

335x335x835

350x290x160

XXQ-3505

200-350

3.2

4.0X4.0

40°+5°

60

42

11

335x335x835

350x290x160

Standard Delivery

Directional glass X-ray tube

1 Pcs

Generator

1 Set

 

High voltage joins cable

1 Pcs

25 Meters

Controller

1 Set

 

Power cable

1 Pcs

10 Meters

Grounding cable

1 Pcs

5 Meters

Accessories

1 Set

 

(Including: alarm lamp, 1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc)

Panoramicradiation portableX-rayflaw detector


(Glass x-raytube)

XXH series are suitable for the welding line detection of little pipe.

Installing carrying wheel or pipeline creeping device, convenient to set up in pipeline (controller also may enter pipeline with generator together), once exposure complete one week welding line detection.

Feature:


●Checking the software and hardware itself after start the machine

●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports

●Can adjust exposure parameters with keys ( easy operation.)

●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field

●Can adjust high voltage slowly for protecting X-ray generator

●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.

●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming

●Convenient for repairing and maintenance

●Much more Substance for structure designing, much more convenient for local operation

●Time can be changed for±0.3 according to the power supply net to make the exposure more precise

Specification:

Output voltage

(Kv)

Input

(KW)

Focus spot

(mm)

Beam angle

Max penetration

(mm)

Weight (KG)

Dimensions (mm)

Level target

Cone target

Level target

Cone target

Generator

Controller

Generator

Controller

XXH-1005

50-100

1.2

1.0x3.5

25°+5°

8

8.5

9.4

Ф135x555

305x338x140

XXH-1605

60-160

1.5

1.0x3.5

25°+5°

11

17

11

225x225x600

350x290x160

XXH-2005

100-200

2.0

1.0x3.5

25°+5°

30°+5°

27

24

22.5

11

280x280x650

350x290x160

XXH-2505

150-250

2.5

1.0x2.4

25°+5°

30°+5°

37

34

33.5

11

320x320x740

350x290x160

XXH-3005

170-300

3.0

1.0x3.5

25°+5°

30°+5°

47

40

42

11

335x335x835

350x290x160

XXH-3205

180-320

3.2

1.0X4.0

25°+5°

30°+5°

50

45

42

11

335x335x835

350x290x160

XXH-3505

200-350

3.2

1.0X4.0

25°+5°

30°+5°

55

52

42

11

335x335x835

350x290x160

Standard Delivery

Directional glass X-ray tube

1 Pcs

Generator

1 Set

 

High voltage joins cable

1 Pcs

25 Meters

Controller

1 Set

 

Power cable

1 Pcs

10 Meters

Grounding cable

1 Pcs

5 Meters

Accessories

1 Set

 

(Including: alarm lamp, 1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc)

Directional radiation portable X-ray flaw detector

(Ceramic X-ray Tube)

XXGseries areceramic X-ray tube, both can be directional model and Panoramic, it is more durable than the glass tube: shake proof and long working life.

Feature:


●Checking the software and hardware itself after start the machine

●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports

●Can adjust exposure parameters with keys ( easy operation.)

●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field

●Can adjust high voltage slowly for protecting X-ray generator

●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.

●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming

●Convenient for repairing and maintenance

●Much more Substance for structure designing, much more convenient for local operation

●Time can be changed for±0.3 according to the power supply net to make the exposure more precise

Specification

Output voltage

(Kv)

Input

(KW)

Focus spot

(mm)

Beam angle

Max penetration

(mm)

Weight (KG)

Dimensions (mm)

Generator

Controller

Generator

Controller

XXG-1605

60-160

1.5

0.8X0.8

40°+5°

18

17

11

225x225x600

350x290x160

XXG-2005

100-200

2.0

2.0X2.0

40°+5°

29

22.5

11

280x280x650

350x290x160

XXG-2505

150-250

2.5

2.0X2.0

40°+5°

38

33.5

11

320x320x745

350x290x160

XXG-3005

170-300

3.0

2.5X2.5

40°+5°

50

42

11

335x335x835

350x290x160

Panoramic radiation portable X-ray flaw detector

(Ceramic X-ray Tube)

XXGseries areceramic X-ray tube, both can be directional model and Panoramic, it is more durable than the glass tube: shake proof and long working life.

Feature:


●Checking the software and hardware itself after start the machine

●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports

●Can adjust exposure parameters with keys ( easy operation.)

●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field

●Can adjust high voltage slowly for protecting X-ray generator

●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.

●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming

●Convenient for repairing and maintenance

●Much more Substance for structure designing, much more convenient for local operation

●Time can be changed for±0.3 according to the power supply net to make the exposure more precise

Specification

Output voltage

(Kv)

Input

(KW)

Focus spot

(mm)

Beam angle

Max penetration

(mm)

Inquiry Cart 0